Woodstock D2722 User Manual

Page of 44
-
7
-
Ground.this.machine! The electrical cord sup-
plied with the W1669 and W1670 Radial Drill
Press comes with a grounding pin. 
DO.NOT 
remove the pin if your outlet does not accept a 
ground pin, see 
Figure.4. Have the outlet box 
replaced by a qualified electrician or have an 
appropriate adapter installed. 
Remember, an adapter with a grounding wire 
does not guarantee the machine will be ground-
ed. A ground source must always be verified in
the electrical circuit within the wall or conduit.
Grounding
ELECTRICAL
110V.Operation
The SHOP FOX
®
W1669 and W1670 Radial Drill
Presses operate at 110 volts only. The motor
supplied with your new drill press is rated at 
1⁄2 HP and will draw approximately 5 amps.
When choosing an outlet for this machine, con-
sider using one with a 15 amp circuit breaker 
or fuse. Keep in mind that a circuit being used
by other machines or tools at the same time 
will add to the electrical load being applied by 
the drill press. Add up the load ratings of all
machines on the circuit. If this number exceeds 
the rating of the circuit breaker or fuse, use a 
different outlet.
DO.NOT modify an existing low-amperage 
circuit by only replacing the circuit breaker 
with a breaker rated for a higher amperage. 
The breaker and the complete circuit must be 
replaced by a qualified electrician.
Any. electrical. outlet. and.
circuit. that. you. plug. your.
machine. into. must. be.
grounded.. Serious. injury.
and/or.fire.may.occur.if.this.
warning.is.ignored!
Figure.4..Never remove a grounding pin.
If you must use an extension cord, use the guide-
lines below to determine the correct cord length 
and gauge. If you use an undersized-gauge exten-
sion cord or one that is too long, heat will gener-
ate in the cord and fire or circuit damage may 
result.
•Use.a.cord.rated.for.Standard.Service.(Grade.S)
•Use.a.cord.that.is.16.gauge.and.100.feet.or.........
..less
•Use.a.cord.with.a.ground.wire.and.pin
•Use.only.undamaged.cords
Extension.Cords
ELECTRICAL