Lincoln Electric TIG 175 PRO User Manual

Page of 32
13
TROUBLESHOOTING
13
SQUARE WAVE TIG 175 PRO
Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility 
for technical troubleshooting assistance before you proceed.
CAUTION
OUTPUT PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
Machine is Dead - 
No Output - No Fan
Fan runs - No output from machine
in either Stick or TIG modes.
Fan runs - No output from machine
in either Stick or TIG modes and the
yellow light on the control panel is
on.
Machine does not respond (no gas
flow, no high frequency and no open
circuit voltage) when arc start switch
or Amptrol is activated -  fan is work-
ing.
1.
Make certain that the input 
power switch is in the “ON”
position and machine is plugged in.
2.
Check the input voltage at the
machine. Input voltage must
match the rating plate and voltage
connection. Refer to Reconnect
Procedure in the Installation sec-
tion of this  manual.
3.
Blown or missing fuses in 
input line.
1.
Check for proper input voltages
per nameplate and voltage
reconnection.
2.
Check to make sure polarity
switch is not in between two
positions.
1.
Welding application may have
exceed the recommended duty
cycle. Allow the unit to run until
the fan cools the unit and the
yellow light goes out.
1.
Machine MUST be in  
the TIG Mode.
2.
The Amptrol may be defective.
Check for continuity between
pins “D” and “E” on cable con-
nector when Amptrol is
depressed.
Contact your Local  Lincoln Authorized
Field Service Facility 
for technical
troubleshooting assistance.