IBM 9077 User Manual

Page of 342
108
 
IBM 9077 SP Switch Router: Get Connected to the SP Switch
4.1.5  Specify Ethernet Card Parameters
As already mentioned, modifying the following profiles is optional.
  • Card Profile - Card Parameters 
  • Load Profile - Run-time Code
  • Dump Profile - Dump Defaults
Only for the configuration of the interface mode these profiles need to be 
modified. You would at least like to know whether FDX and HDX settings are 
suited to your environment and change them, if needed.
We advise that you set the ports explicitly to the values you expect them to 
have according to your network layout. We prefer to have control over the 
network, instead of it controlling us (which might be wishful thinking).
Set the Negotiation or Transfer Rate
Set the negotiation or transfer rate in the 
ports/ether
 field. By default, the 
setting for each interface is autonegotiate:
super> read card 7
CARD/7 read
super>list ports 1
port_num = 1
cisco-hdlc = { off on 10 3 }
fddi = { single off }
sonet = { "" "" 1 sonet internal-oscillator 0 207 }
hssi = { 0 16-bit }
ether = { autonegotiate }
hippi = {1 32 no-mode 999999 4 incremental 5 300 10 10 03:00:0f:c0 disab+
super> list ether
if-config = autonegotiate
At this level, use the 
set
 command to look at the interface options:
super> set if-config ?
#name   address         netmask         broad_dest      arguments
ge070  10.20.30.1       255.255.255.0   -               mtu 1500
#ge071  10.20.30.1      255.255.255.0   -               mtu 1500
#ge072  10.20.30.1      255.255.255.0   -               mtu 1500
#ge073  10.20.30.1      255.255.255.0   -               mtu 1500
#ge074  10.20.30.1      255.255.255.0   -               mtu 1500
#ge075  10.20.30.1      255.255.255.0   -               mtu 1500
#ge076  10.20.30.1      255.255.255.0   -               mtu 1500
#ge077  10.20.30.1      255.255.255.0   -               mtu 1500