2.
Set the switches on the bottom of the dome drive. Refer to Table A for the settings for
SW1, and Table B and Table C for SW2.
3.
Install the dome drive in the back box. Line up the green tab and red tab on the dome
drive with the green label and red label on the back box. Raise the dome drive into the
back box and push on the ends of the tabs until they both click into place on the back box.
4.
Turn on power, if it is not on. Listen for the fan operating. If the fan does not work, the
dome will overheat and shut down. If the fan does not work, return the back box
electronic assembly and dome drive to the factory for repair. Refer to the 
Back Box
Electronic Assembly Removal 
section in manual C1487M-C.
CAUTION:
 Make
sure the dome
drive locks into
place. Pull down on the
dome drive with moderate
pressure to ensure that it
stays in place.
Table A.  Switch Settings for SW1
Control Type
Switch Setting
SW1-1
SW1-2
SW1-3
SW1-4
SW1-5
SW1-6
SW1-7
SW1-8
Coaxitron
®
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF**
P-Type Control
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF**
D-Type Control
OFF
ON
OFF
OFF
OFF
OFF
OFF*
OFF**
NOTES:
Switches SW1-3 through SW1-6 MUST be OFF.
D-type control is RS-422 that is compatible with Pelco‘s CM6700, MPT9500 and CM8500
   controllers or with American Dynamics control systems using the AD2083 Translator.
P-type control is RS-422 that is compatible with Pelco's CM6700/CM9750/CM9760 control
   systems.
* OFF - Use with controllers that have more than 32 presets.
ON - Use with American Dynamics controllers (32 presets).
** OFF - Use with all control systems except CM9502 with variable speed keyboards.
For CM9502 with fixed speed keyboards, set switch OFF.
ON - Use with CM9502 with variable speed keyboards for smoother joystick control.
Table B.  Switch Settings for SW2 – P-Type Control
NOTE:
For Coaxitron
®
 controls, SW2 is not used; set all switches OFF.
For D-type control systems, refer to Table C.
Receiver Address
Switch Setting
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
1
OFF
OFF
OFF
OFF
OFF
2
ON
OFF
OFF
OFF
OFF
3
OFF
ON
OFF
OFF
OFF
4
ON
ON
OFF
OFF
OFF
5
OFF
OFF
ON
OFF
OFF
6
ON
OFF
ON
OFF
OFF
7
OFF
ON
ON
OFF
OFF
8
ON
ON
ON
OFF
OFF
9
OFF
OFF
OFF
ON
OFF
10
ON
OFF
OFF
ON
OFF
11
OFF
ON
OFF
ON
OFF
12
ON
ON
OFF
ON
OFF
13
OFF
OFF
ON
ON
OFF
14
ON
OFF
ON
ON
OFF
15
OFF
ON
ON
ON
OFF
16
ON
ON
ON
ON
OFF
17
OFF
OFF
OFF
OFF
ON
18
ON
OFF
OFF
OFF
ON
19
OFF
ON
OFF
OFF
ON
20
ON
ON
OFF
OFF
ON
21
OFF
OFF
ON
OFF
ON
22
ON
OFF
ON
OFF
ON
23
OFF
ON
ON
OFF
ON
24
ON
ON
ON
OFF
ON
25
OFF
OFF
OFF
ON
ON
26
ON
OFF
OFF
ON
ON
27
OFF
ON
OFF
ON
ON
28
ON
ON
OFF
ON
ON
29
OFF
OFF
ON
ON
ON
30
ON
OFF
ON
ON
ON
31
OFF
ON
ON
ON
ON
32
ON
ON
ON
ON
ON
Baud
Switch Setting
Rate SW2-6 SW2-7 SW2-8
2400
OFF
OFF
OFF
4800
ON
OFF
OFF
9600
OFF
ON
OFF