Panasonic 324566-A User Manual

Page of 172
Nortel Secure Router 8012 
Hardware Description 
5 Cables 
 
Issue 5.3 (6 April 2009) 
Nortel Networks Inc. 
5-25 
 
DB78 
Signal 
Signal direction 
Signal 
RJ45 
11 CABLE_TY
PE_SEL1 
ÅPGND —  — 
20 PGND 
— 
 
— 
21 PGND 
— 
 
— 
30 PGND 
— 
 
— 
39 PGND 
— 
 
— 
40 PGND 
— 
 
— 
49 PGND 
— 
 
— 
50 PGND 
— 
 
— 
59 PGND 
— 
 
— 
60 PGND 
— 
 
— 
69 PGND 
— 
 
— 
78 PGND 
— 
 
— 
 
5.7.4 4CT1/8CT1 interface cable 
The 4CT1/8CT1 interface module of Secure Router 8012 is connected with the 120-ohm 
shielded twisted-pair cable. 
Figure 5-8 shows the outline of the 4CT1 cable and Table 5-7 shows the pin assignment. 
Figure 5-10 shows the outline of the 8CT1 cable and Table 5-9 shows the pin assignment. 
5.7.5 16CT1 interface cable 
The 16CT1 interface cable for the Secure Router 8012 is a 120-ohm shielded twisted-pair 
cable. Figure 5-12 shows the outline of the 16CT1 cable and Table 5-11 shows the pin 
assignment. 
5.8 
Channelized E3 interface cable 
5.8.1 Introduction 
The 1CE3 interface module provides two SMB interfaces, which are connected to the Tx end 
and Rx end of the peer device. The interfaces work in 75-ohm unbalanced transfer mode and 
are connected with the peer device through a pair of 75-ohm unbalanced coaxial cables. 
5.8.2 Structure 
Figure 5-13 shows the outline of the 1CE3 interface cable.