Panasonic 324566-A User Manual

Page of 172
3 Heat dissipation system 
Nortel Secure Router 8012 
Hardware Description 
 
3-4 
Nortel Networks Inc. 
Issue 5.3 (6 April 2009) 
 
The heat dissipation system of the Secure Router 8012 ventilates the Secure Router 8012. 
From the top, the air flow enters the Secure Router 8012 from the left and exits from the right. 
Figure 3-3 shows the air flow inside the Secure Router 8012.   
Figure 3-3 Air flow inside the Secure Router 8012 
Fan module frame
 
 
3.3 Technical specifications 
Table 3-2 shows the technical specifications of the fan module. 
Table 3-2 Technical specifications of the fan module
 
Item 
Specifications 
Dimensions 
259.45 mm (H) x 47.70 mm (W) x 462.65 mm (D) 
Power consumption 
38.4 W 
Maximum blast pressure 
75 Pa 
Maximum blast volume 
921.6 m
3
/h 
Maximum noise 
60 dB 
Maximum rev 
3800 RPM 
Operating voltage range 
7.0 V to 13.8 V DC 
Operating voltage 
12 V DC