Panasonic 324566-A User Manual

Page of 172
4 Boards 
Nortel Secure Router 8012 
Hardware Description 
 
4-28 
Nortel Networks Inc. 
Issue 5.3 (6 April 2009) 
 
Table 4-28 Description of the indicators of channelized and unchannelized E1/T1 interface 
modules 
Indicator 
State and significance 
LINK 
If the indicator is ON, the link is connected. If the indicator is OFF, the 
link is disconnected. 
ACT
 
If the indicator is OFF, no data is being transmitted or received. If the 
indicator is flashing, data is being transmitted or received. 
0–3 (4E1/T1) 
0–7 (8E1/T1) 
E0–E15 (16E1/T1) 
The indicators corresponding to the relevant 
port number. 
 
4.7.3 Interface attributes 
Table 4-29 shows the attributes of the channelized and unchannelized E1/T1 interface module. 
Table 4-29 Attributes of the channelized and unchannelized E1/T1 interface modules 
Description 
Attribute 
4/8E1 
4/8/16CE1 
4/8CT1 
16CT1 
Connector type 
z
 
DB-68 (4/8E1,4/8CE1 and 4/8CT1) 
z
 
DB-78 (16CE1 and 16CT1) 
Operating 
mode 
E1 
E1 and CE1 
T1 and CT1 
Transmission 
rate 
z
 
In E1 mode: 2048 kbit/s 
z
 
In CE1 mode: N x 64 kbit/s (N = 
1 to 31) 
z
 
In T1 mode: 1544 kbit/s 
z
 
In CT1 mode: N x 56 kbit/s and 
N x 64 kbit/s (N = 1 to 24) 
Cable model 
75 coaxial cable 
120 shielded twisted pair cable 
120 shielded twisted pair cable 
Maximum 
transmission 
distance 
75 coaxial cable: 0.5 km 
120 shielded twisted pair cable 0.15 
km 
0.15 km 
Interface 
standard 
ITU-T G.703 and ITU-T G.704 
Supported 
network 
protocol 
IP 
Other 
supported 
protocols 
PPP, LAPB, X.25, Frame Relay, HDLC, and MP (16CE1/16CT1 
supports PPP, HDLS, and MP.)