Ryobi A25RT02 User Manual

Page of 20
7
ELECTRICAL
SPEED AND WIRING
The no-load speed of this product depends on the router 
you are using. This speed is not constant and decreases 
under a load or with lower voltage. For voltage, the wiring 
in a shop is as important as the motor’s horsepower rating. 
A line intended only for lights cannot properly carry a power 
product motor. Wire that is heavy enough for a short dis-
tance will be too light for a greater distance. A line that can 
support one power product may not be able to support two  
or three products.
GROUNDING INSTRUCTIONS
In the event of a malfunction or breakdown, grounding pro-
vides a path of least resistance for electric current to reduce 
the risk of electric shock. This product is equipped with an 
electric cord having an equipment-grounding conductor and 
a grounding plug. The plug must be plugged into a matching 
outlet that is properly installed and grounded in accordance 
with all local codes and ordinances.
Do not modify the plug provided. If it will not fit the outlet, 
have the proper outlet installed by a qualified electrician. 
Improper connection of the equipment-grounding conduc-
tor can result in a risk of electric shock. The conductor with 
insulation having an outer surface that is green with or without 
yellow stripes is the equipment-grounding conductor. If repair 
or replacement of the electric cord or plug is necessary, do 
not connect the equipment-grounding conductor to a live 
terminal.
Check with a qualified electrician or service personnel if the 
grounding instructions are not completely understood, or if 
in doubt as to whether the product is properly grounded.
Repair or replace a damaged or worn cord immediately.
This product is intended for use on a circuit that has an outlet 
like the one shown in figure 1. It also has a grounding pin 
like the one shown. 
Fig. 1 
EXTENSION CORDS
Use only 3-wire extension cords that have 3-prong grounding 
plugs and 3-pole receptacles that accept the product’s plug. 
When using a power product at a considerable distance from 
the power source, use an extension cord heavy enough to 
carry the current that the product will draw. An undersized 
extension cord will cause a drop in line voltage, resulting in 
a loss of power and causing the motor to overheat. Use the 
chart provided below to determine the minimum wire size 
required in an extension cord. Only round jacketed cords 
listed by Underwriter’s Laboratories (UL) should be used.
**Ampere rating  (on product data plate)
 
 
0-2.0 
2.1-3.4 
3.5-5.0  5.1-7.0  7.1-12.0   12.1-16.0
Cord Length   
 Wire Size (A.W.G.)
  25' 
16 
16 
16 
16 
14 
14
  50' 
16 
16 
16 
14 
14 
12
  100' 
16 
16 
14 
12 
10 
**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge
When working with the product outdoors, use an extension 
cord that is designed for outside use. This is indicated by the  
letters “WA” on the cord’s jacket.
Before  using  an  extension  cord,  inspect  it  for  loose  or  
exposed wires and cut or worn insulation.
WARNING:
Keep  the  extension  cord  clear  of  the  working  area. 
Position the cord so that it will not get caught on lumber, 
products or other obstructions while you are working with 
a power product. Failure to do so can result in serious 
personal injury.
WARNING:
Check  extension  cords  before  each  use.  If  damaged 
replace immediately. Never use product with a damaged 
cord since touching the damaged area could cause elec-
trical shock resulting in serious injury.
ELECTRICAL CONNECTION
This product should be connected to a 
power supply that is 
120 volts, 60 Hz, AC only (normal household current). Do 
not operate this product on direct current (DC). A substantial 
voltage drop will cause a loss of power and the motor will 
overheat. If the router table does not operate when plugged 
into an outlet, double check the power supply.
GROUNDING 
PIN
120 V GROUNDED OUTLET