Denso BHT-7500S User Manual

Page of 217
97
Chapter 2.  Getting Started the BHT and System Mode
          SET ID
  1:DOMAIN        0
  
2:SECURITY ID
  [********************]
      Set up?
          1:Yes 
2:No
Shown at left is an entry sample screen where a
security ID is DENSO WAVE.
After entry, press the  ENT  key. Instead of the
"DENSO WAVE" entered, 20 asterisks will display.
Pressing the  SF  key switches the entry mode
between the numeric mode (without a guidance)
and alphabet mode.
In the entry mode, to delete a single character,
press the  BS  key ( SF  +  C  keys).  To delete the
whole entry you made, press the  C  key.
Pressing the  C  key when any item is highlighted
will display the confirmation message as shown at
left.
To save the new entry, choose "1:Yes" and press
the  ENT  key.  The "** Now Setting **" will appear
and the screen will return to the RF MENU.
To cancel the new entry, choose "2:No" and press
the  ENT  key.  The newly entered value will be
discarded and the screen will return to the RF
MENU.
When the "** Now Setting **" displays, the
newly entered security ID will be written onto
the EEPROM of the wireless module built in
the BHT-7500S.
While this message is displayed, do not turn
the BHT off.  Writing halfway onto the
EEPROM will not bring any assured settings.
Be sure to record your security ID.  There is
no way to read it out from the EEPROM of
the wireless module.
As long as you do not set a new security ID,
the previous setting will be retained.
When setting a security ID, pressing the  ENT
key without entering any character string will
set a default value to the EEPROM of the
wireless module.
          SET ID
  
1:DOMAIN        
0
  2:SECURITY ID
  [DENSO WAVE           ]  
BHT-7500S