8.  High-speed Program Server 
8.3  Host (Compatible with M60S Series) 
 
 
I-328 
(Note 3) 
 
(1)  If the same device is set for device A and device B, an error will occur. 
 
(2)  Set the IC card device's file name as an identifier (max. 8 characters) + extension (max. 3 
characters). If a file name exceeding this number of characters (a long file name), an operation 
error (E84) will occur, and the file will not be transmitted. 
 
 
(Example)  File name usable for IC card device 
OK (transfer possible) ..................12345678.PRG 
NG (transfer not possible) ............123456789.PRG 
 
(3)  The directory created in the IC card (created on the personal computer) can have up to 18 
hierarchies. If a file is transferred or a directory is moved (file list displayed) to a directory having 
more than 18 hierarchies, an operation error (E319) will occur, and the file cannot be transferred or 
listed. 
 
(4)  There is an upper limit to the number of files (approx. 200 files: differs for each IC card) that can be 
created in the IC card's root directory (directory immediately below the IC card drive). If files 
exceeding this upper limit are transferred, an operation error (E51) will occur, and the file will not 
be transferred. 
 
(Note)  Normal file transfer may not be possible with an IC card used in (2) to (4) above. (This also 
applies when operation are carried out on the PC.) 
If an operation error (E51) occurs, format the IC card. 
 
(5)  When the memory device programs and IC card or host device files are compared, the following 
line will be ignored. 
 
Line not subject to comparison 
• Line containing a "%" code (when "%" is described at head of file) 
• "0" No. + comment line 
 
 
Use the CR+LF code for the carriage return code of the IC card or host device file. Files that do not 
use the CR+LF code for carriage return cannot be compared. An operation error (E35) will occur if 
compare is attempted. 
 
(Note 4)  Only the files in the memory and IC card can be erased. 
 
(Note 5)  When using the 2-part system, the device name is memory and the directory is /PRG/USER, the 
name of the selected system can be displayed. Whether to show or hide name of the selected 
system can be switched with the parameters. 
#1050 
MemPrg 
#1285 
ext21/bit0 
#1286 
ext22/bit0
Details 
0, 2, 4, 6 
The name of the selected system is not displayed. 
1, 3, 5, 7 
OFF 
 
  
OFF 
The name of the selected system is displayed. 
 
ON 
ON 
The name of the selected system is not displayed. 
 
(Note 6)  When parameter (#1220 aux04 (bit7)) is set, automatic start can be executed while communicating 
with the host (during input/output). However, the machining performance could be affected.