Sharp JW-20FL5 User Manual

Page of 224
6-8
Chapter 6: Connection/Wiring
6
[4] Connection of JW-50FL
(1) Connection of 10BASE5
This paragraph describes how to connect 10BASE5 cable to the JW-50FL.
 Connecting the transceiver cable
1
 Slide the lock on the 10BASE5 connector (on the JW-50FL) up.
2
 Insert the connector so that the two locking posts on the cable connector match the holes on
the slide lock.
3
 Slide the lock down to lock the cable connector.
 Wiring the power source
When a 10BASE5 is used, 12 VDC power should be supplied to the transceiver.
Supply power to the 12 VDC power terminals using a commercial constant voltage power supply
unit.
Remarks
- Use a power supply that is dedicated for use by the JW-50FL.
- Do not reverse the positive and negative connections to the power terminals. Reversing the
polarity may damage the JW-50FL.
① 
↑ ↓ 
  ③ 
② 
 
Locking post
Transceiver cable
Slide lock
10BASE5 connector
Locking post
10B5
10B-T
12VIN
(+) 
(−) 
FG 
RESET
(+) 
(−) 
12 VDC
* Fuse (0.6 A)
Black wire (-)
Red wire (+)
Twisted pair wires
Case
Green wire 
(ground)
Cable
(Accessory: Connector, cable length 1.5 m)
* Use a fuse melt with time lag
Item
Specifications
Supply voltage
Current capacity
12 VDC 
5%
0.5 A minimum.