Sharp JW-50FL User Manual
![Sharp](https://files.manualsbrain.com/attachments/09c3752719497cddb7682a2870f2b01d664ac839/common/fit/150/50/128db0ff9ffd18d046ef9a246eb7bdc77b15206699c58d5f48a715e1dba1/brand_logo.png)
7-4
Chapter 7: Computer Link Function
7
Parameters related to the system configuration are summed up below.
General specifications for configuring an Ethernet system
[2] 10BASE-T system
Connect a hub to a transceiver using a transceiver cable, and the hub can be connected to multiple
nodes. This system is shown below.
When you want to connect a node to a hub, use twisted pair cable (10BASE-T).
nodes. This system is shown below.
When you want to connect a node to a hub, use twisted pair cable (10BASE-T).
Basic connections in a 10BASE-T system
If distance between the nodes is not too great, you can connect a twisted pair cable to a hub directly,
without using a coaxial cable or transceiver.
without using a coaxial cable or transceiver.
Item
Specifications
Maximum length of a segment
500 m
Maximum number of transceivers that can be
installed within one segment
installed within one segment
100
Maximum distance between nodes
2500 m or less (except for the transceiver cables)
Maximum number of nodes in a system
254
Maximum length of transceiver cable (AUI cable) 50 m
Cable length between transceiver and repeater
2 m or less (recommended)
Maximum number of repeaters between two
nodes
nodes
2 (However, a link segment is treated as one
repeater, even though it has a repeater at each end.)
: Twisted pair cable
(10BASE-T)