Toshiba 350 User Manual

Page of 302
13 - 12
13
e-STUDIO350/352/353/450/452/453
FUSER UNIT / PAPER EXIT SECTION
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
(7)  Abnormality detection by the thermistors
The following table shows the conditions judging the fuser belt temperature abnormality and detecting timing.
*  The figures in the “condition” section denote the priority of error checking.
Checking timing
Condition
Temperature judged
Checking
timing
Error
code
Main thermistor
Front edge thermistor
Power ON
1
230°C or above
280°C or above
Power ON
C440
-
-
Detecting
40°C
1
230°C or above
280°C or above
Fixed time
C440
-
-
2
40°C or below
-
C410
-
-
Detecting
100°C
1
230°C or above
280°C or above
Fixed time
C440
-
-
100°C or below
-
-
-
Detecting
160°C
1
230°C or abov e
280°C or above
Fixed time
C440
-
-
160°C or below
-
-
Detecting
ready
temperature
1
230°C or above
280°C or above
Fixed time
C440
-
-
Ready temp. or below
-
-
-
During ready
status
At Energy
Saving Mode
1
230°C or above
280°C or above
On usual
C440
-
-
40°C or below
-
-
-
During printing
1
230°C or above
280°C or above
On usual
C440
-
-
40°C or below
-
-
-
2
-
-
C450
At paper jam
1
230°C or above
40°C or below
On usual
C440
-