Toshiba 350 User Manual

Page of 302
e-STUDIO350/352/353/450/452/453
GENERAL OPERATION
4
4 - 1
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
4.  GENERAL OPERATION
4.1  Overview of Operation
Operation of equipment
Operation during initializing, pre-running and ready
Drawer feed copying by [START] button
Copying operation
Bypass feed copying
Interrupt copying
4.2  Description of Operation
4.2.1  Warming-up
(1)  Initialization
•  Power ON
•  IH coil ON
•  Set number “1” reproduction ratio “100%” and “WAIT WARMING UP” are displayed
•  Fan motors ON
•  Initialization of scanning system
 – The carriage moves to the home position.
 – The carriage moves to the peak detection position.
 – The exposure lamp is turned ON.
 – Peak detection (white color is detected by the shading correction plate)
 – The exposure lamp is turned OFF.
•  “READY (WARMING UP)” is displayed
(2)  Pre-running operation
The pre-running operation is started when the temperature of the fuser roller surface reaches a
certain temperature.
•  Fuser roller rotated
•  Drum rotated
 – The main motor is turned ON.
•  Initialization of feeding system
 – Each drawer tray goes up.
•  Pre-running operation stops after five seconds.
(3)  When the surface temperature of the fuser roller becomes sufficient for fusing,
•  “READY” is displayed.