Motorola CPX8216TCPX8216T User Manual

Page of 193
Switch Settings
4-3
4
Switch Settings
Use this table as a guideline for configuring the 6-position dip switch on 
your PMC.
Terminators - The SCSI bus (cable) must be properly terminated at each 
end of the bus. The first and last device on the bus should be the only 
devices that are set to terminate the bus. 
Terminator Power - The SCSI terminators require adequate voltage to 
properly terminate the SCSI bus. All SCSI host adapters on the bus should 
be set to supply terminator power; and where possible, be located at the 
end of the bus and serve as bus terminators.The terminator resistors must 
be present on the first and last device on the bus only.
For further information on this PMC, visit the 
web site at 
Table 4-1. PMC Switch Settings
Switch
On Function
Off Function
Default
1
Use INTA
No Use INTA
On
2
Use INTB
No Use INTB
Off
3
Use INTC
No Use INTC
Off
4
Use INTD
No Use INTD
Off 
5
TERM Enable
TERM Disable
On
6
Little Endian
Big Endian
On
Configure the Big/Little endian mode to your appropriate application for proper 
software operation.
Make sure only one INTx line switch is in the ON position.
Enable TERM ENAB is On only if this SCSI controller is physically at the end 
of the SCSI bus. If the SCSI controller is in any other position on the bus, TERM 
ENAB must be in the OFF mode.