Netgear PS100 User Manual

Page of 142
NetGear Print Server Manual 
23 
Logical Printer 
The logical printer screen is used to map different logical printer ports to printers attached to the Print 
Server. A logical printer port is used to specify a set of printer control commands to be sent to a printer 
for every print job sent through the logical port. Figure 3-8 shows the logical port screen and the 
following table describes its fields. 
  
 
Figure 3-8 Logical Port Screen  
 
Logical Port Fields 
Logical Port Selects the logical port to be configured. Three logical ports are available. 
Get Data  
Click this button to display the saved configuration parameter for the selected logical port. 
Pre-String 
(Hex) 
Provides the control character string to send to the printer before the first character of the job is sent to the 
printer. One example of such an application would be switching to landscape mode when printing to the logical 
port. The string is made up of the hexadecimal code of the corresponding ASCII characters, as in these 
examples: 
ASCII = [Esc]&|0O 
Hexadecimal = 1B266C304F 
ASCII=[Esc]&|1O 
Hexadecimal = 1B266C314F 
An ASCII to hexadecimal number conversion table is include in the appendix.  
Post-String 
(Hex) 
Provides the control character string to send to the printer after the last character of the job is sent to the 
printer. The character string must be in hexadecimal format as illustrated in the String Before Job example 
above. 
Convert LF 
to CR/LF 
If checked, adds a carriage return (CR) every time the line feed (LF) character code is received by the print 
server when print data is sent to this logical printer port. Generally this should be unchecked. It may be needed 
for compatibility between Unix and Windows. 
Save 
Cancel  
Save: 
After the configuration, click on ‘Save’ button to save the value permanently.