Toshiba e-STUDIO451c User Manual

Page of 602
June 2005 © TOSHIBA TEC
e-STUDIO281c/351c/451c ADJUSTMENT
3 - 5
3
3.3
Performing Image Quality Control
(1) When unpacking
Prior to image dimensional adjustment, perform the “Automatic initialization of image quality con-
trol (05-396)” procedure.
(2) When any of the following parts is replaced, be sure to perform the “Automatic initialization of 
image quality control (05-396)” procedure.
• Photoconductive drum 
• Developer material 
• Laser optical unit
• Image quality sensor
• Transfer belt 
• 1st transfer roller
• 2nd transfer roller 
• Main charger 
• Main charger grid
• Drum cleaning blade 
• Drum cleaner brush
Note: 
Note: 
When performing "Automatic gamma adjustment" in addition, “Automatic initialization of image 
quality control (05-396)” should be done first.
(3) When performing "Automatic gamma adjustment" in cases no parts written above are replaced, 
do the “Forced performing of image quality closed-loop control (05-395)” procedure before "Auto-
matic gamma adjustment".
Code
Item to be adjusted
Contents
395
Forced performing of 
image quality closed-loop 
control
<Procedure>
1) While pressing [0] and [5] simultaneously, turn the power ON.
→ Adjustment Mode
2) Key in [395] and press the [START] button.
3) "WAIT" is displayed.
4) When the adjustment finishes normally, the equipment returns to the 
initial state of Adjustment Mode. If an error has occurred, take appro-
priate action by referring to “5. TROUBLESHOOTING”.
396
Automatic initialization of 
image quality control
<Procedure>
1) While pressing [0] and [5] simultaneously, turn the power ON.
→ Adjustment Mode
2) Key in [396] and press the [START] button.
3) "WAIT" is displayed.
4) When the adjustment finishes normally, the equipment will return to 
initial state of the Adjustment Mode. If an error has occurred, take 
appropriate action by referring to “5. TROUBLESHOOTING”.