e-STUDIO281c/351c/451c ADJUSTMENT
3 - 59
3
3.11.2
Doctor-to-sleeve gap (color developer unit)
Adjustment tool to use : Doctor-sleeve jig
Adjusting procedure:
(1) Take off the color developer unit from the equipment.
(2) Remove 2 screws, release 5 hooks and take
(2) Remove 2 screws, release 5 hooks and take
off the developer material cover. Then dis-
charge the developer material.
charge the developer material.
Fig.3-32
(3) Remove 4 screws and the toner-scattering
prevention seal holder.
Fig.3-33
(4) Loosen 2 doctor blade fixing screws. Insert
the gauge “0.55” of the doctor-sleeve jig
between the developer sleeve and doctor
blade to adjust the gap, and tighten the
screws.
between the developer sleeve and doctor
blade to adjust the gap, and tighten the
screws.
Fig.3-34
Screw
Screw
Developer material cover
Screw
Toner-scattering prevention
seal holder
seal holder
Doctor-sleeve jig
Developer sleeve
Doctor blade
Screw