e-STUDIO281c/351c/451c PREVENTIVE MAINTENANCE (PM)
4 - 9
4
4.2
General Descriptions for PM Procedure
(1) Preparation
• Ask the user about the current conditions of the equipment and note them down.
• Before starting maintenance, make some sample copies and store them.
• See the replacement record and check the parts to be replaced in the PM support mode (6S- 
2) or list printing mode (9S-103).
6S-2
: [6] + [START] + [POWER] ON Æ [2] Æ [START]
9S-103 : [9] + [START] + [POWER] ON Æ [103] Æ [START]
 Fig.4-7
• Turn OFF the power and make sure to unplug the equipment.
(2) Perform a preventive maintenance using the following checklist and illustrations. Refer to the 
Service Manual if necessary.
(3) Plug in the equipment after the maintenance has been finished. Then turn ON the power and 
make some copies to confirm that the equipment is working properly.
PM SUPPORT CODE LIST
XX-XX-'XX 11:28
UNIT 
OUTPUT PAGES/ 
PM OUTPUT PAGE/ 
DRIVE COUNTS 
PM DRIVE COUNTS
 
DEVELOP COUNTS  DEVELOP COUNTS
DRUM 22220 
200000 
30948 
320000
DRUM BLADE 
22220 
200000 
30948 
320000
DRUM BRUSH 
22220 
200000 
30948 
320000
GRID 22220 
200000 
30948 
320000
MAIN CHARGER WIRE 
22220 
200000 
30948 
320000
WIRE CLEANING PAD 
22220 
200000 
30948 
320000