Enterasys Networks 7H4385-49 User Manual

Page of 92
Using LANVIEW
4-4 Troubleshooting
CPU 
(cont’d)
Amber and 
off
Alternating (67% on, 33% 
off)
. Indicates that a 
shutdown process has 
completed. This indication 
will remain for 60 seconds 
before automatically 
restarting. 
While in this state, you have 60 seconds 
to safely remove the DFE module from 
the chassis.
RX/TX Indications in Standard Mode
RX
(Receive)
Off
No link. No activity. Port 
enabled or disabled.
None.
Green
Solid. Link present, port 
enabled, no traffic is being 
received by the interface.
None.
Amber
Flashing. Link present, port 
enabled, traffic is being 
received by the interface.
None.
Red
Blinking. Indicates 
collisions. This indication is 
only supported on 10/100 
ports.
Contact Enterasys Networks for 
technical support.
TX
(Transmit)
Off
Port enabled, but no activity.
If it is known that the port should be 
active and is not, contact 
Enterasys Networks for technical 
support.
Green
Flashing. Indicates data 
transmission activity. Rate of 
flashing indicates the data 
rate.
None.
Red
Flashing. Fault or Error 
(collision).
None, unless there is a high rate of 
activity. In this case, check for network 
configuration problems or a defective 
device.
Table 4-1 LANVIEW LEDs (continued)
LED
Color
State
Recommended Action