JVC LCT2505-001A-H User Manual

Page of 32
20
LAN
<IR OUT system>
Control signals from the remote control of external equipment are sent out to the equipment through the RS-
485 OUT terminal.
About the external control
This monitor has the following external control terminals:
•  RS-232C terminal: Controls the monitor by external control equipment (a personal computer or a dedicated 
controller) (see “Using the serial communication” on page 21).
•  RS-485 terminals: The following external control systems are available.
(1) Serial communication: Controls the monitor by external control equipment (a personal computer or a 
dedicated controller) (see page 21).
(2)  IR OUT system: Controls other equipment through the monitor by using the remote control supplied 
with the equipment.
(3)  MAKE (make contact system): Controls the function by short-circuiting the corresponding pin terminal 
to the GND pin terminal, or disconnecting (opening) it (see page 22).
(4)  TRIG. (trigger system): Controls the function by inputting the pulse signal instantaneously to the 
corresponding pin terminal (see page 22).
•  LAN terminal (10BASE-T): Controls the monitor from a PC in the network through the web browser (see 
“Using the LAN system” on page 23).
Set the following items in “REMOTE SYSTEM” according to the external control terminal and control system 
you use (see page 15).
Control system
“REMOTE IN SEL.” 
setting
“CNT. RJ45 OUT” 
setting
“CNT. RJ45 IN” setting
Serial 
communication 
RS-485
RJ-45*
1
RS485
RS485
RS-232C
D-sub9*
1
RS485
RS485
IR OUT system
Any
IR OUT
Any
MAKE system
RJ-45
RS485
MAKE
TRIG. system
RJ-45
RS485
TRIG.
LAN system*
2
LAN
Any
Any
*
1
 For the monitor connected to the external control equipment, set “REMOTE IN SEL.” according to the actual 
connection. Set other monitors to “RJ-45.”
*
2
 Set “NETWORK SETTING” in the set-up menu (see pages 16 and 23).
NOTE
•  The functions controlled by an external device through the MAKE connection cannot be controlled on the 
main unit or the remote control.
•  While the Control Lock (see page 16) is in use, you can use external control.
<Serial communication>
Several monitors can be controlled by connecting their RS-485 IN and OUT terminals. See also page 21.
Do not use the AC OUT terminal on the monitor for power supply to another monitor.
How to Use External Control
RS-485 IN 
or RS-232C
RS-485 
OUT
RS-485 
IN
RS-485 
OUT
RS-485 
IN
RS-485 
OUT
External control 
equipment
Karaoke 
component, etc.
Remote control
RS-485 
OUT
<MAKE/TRIG. system>
You can control the monitor by external control equipment*
3
. See also page 22.
*
3
 External control equipment is not commercially available. Consult your dealer if you need a dedicated 
controller.
<LAN system>
You can control the monitor from PC in your Local Area Network (LAN) through the web browser.
PC
PC
PC
Hub
Hub
Monitor
GM-F470S_EN.indd   20
GM-F470S_EN.indd   20
08.12.26   10:35:49 AM
08.12.26   10:35:49 AM