Kramer Electronics PL-150 User Manual

Page of 52
Operating Your PL-50 Power Controller – Monitor 
 
27   
6.4 DIP-switch Settings 
 and 
 define the DIP-switches: 
1 2
 
 
Table 9: DIP-switch Definitions 
DIP 
Function: 
PROGRAM, for factory use only 
ON for RS-485 Line Termination with 120Ω; 
OFF for no RS-485 Line Termination 
 
 
Figure 29: SETUP DIP-switches 
 
 
7  Operating Your PL-50 Power Controller – Monitor 
You can operate your PL-50 via: 
  The front panel buttons 
  Remotely, by USB, RS-485 or RS-232 serial commands transmitted by a 
touch screen system, PC, or other serial controller 
  The Ethernet 
  Remotely, from the Kramer Infrared Remote Control Transmitter or the 
infrared remote extension cable transmitter 
Powering up PL-50 unit, recalls the previous settings (that is, the state of the unit 
when it was powered down) from the non-volatile memory. 
7.1 Calibrating via the Front Panel Buttons 
Prior to monitoring the PL-50 outlets, each outlet needs to be measured for its 
standby and Active modes. 
To set the Active mode, do the following: 
1.  Press one or more OUT buttons to select the channels for which you want to 
measure the standby or active modes. 
The selected buttons illuminate. 
2.  Set the connected units to the Active mode. 
3.  Press the PRESET LEVEL ACTIVE button. 
The selected orange OUT buttons, and their related ACTIVE green LEDs 
blink. 
4.  Press each of the selected orange blinking buttons to initialize the 
measurement. 
The ACTIVE green LED blinks until measurement is complete.