Tektronix 1740A/1750A User Manual

Page of 143
Operator’s Checkout Procedure
2-12
1740A/1750A Series Waveform/Vector Monitor User Manual
H Connect the generator NTSC output (COMPOSITE for
TSG131) to the CH-A input. Connect the CH-A loop-
through to the EXT REF input and connect a 75
Ω
terminator to the EXT REF loop-through. See
Figure 2-5.
A
A1
A2
A3
B
B1
B2
B3
EXT
REF
1750A
NTSC
NTSC
Y
Y
B-Y
R-Y
TSG 130
Figure 2-5. Equipment hook-up for Operator’s Checkout Procedure.
Procedure
1.
Initialize the Front-Panel Controls
Enter the
PRESET
menu and select
FACTORY
. Press the bezel
button corresponding to
RECALL
. The front-panel controls
are now set to the factory preset (described on page 3-16),
and the
PRESET
menu is automatically exited. Notice that the
instrument is in the
WAVEFORM
display mode with the
CH-A
INPUT
displayed in two-line sweep.
2.
Adjust the Display
Use the
VERT POS
and
HORIZ POS
controls to center the
display.