Planar PL2011 User Manual

Page of 13
 
12 
 
Troubleshooting 
This LCD Monitor has pre-adjusted using factory standard VGA timings. Due to the output timing differences among various 
VGA cards in the market, users may initially experience an unstable or unclear display whenever a new display mode or new 
VGA card is selected. 
Attention 
This LCD Monitor Supports Multiple VGA Modes.   
Refer to the Standard Timing Table for a listing of modes supported by this LCD Monitor. 
PROBLEM    Picture is unclear and unstable 
The picture is unclear and unstable, please perform the following steps : 
1.  Enter PC to “Shut Down Windows” status while you’re in MS-Windows environment. 
2.  Check the screen to see if there’s any black vertical stripes appear. If there are, take advantage of the “Clock” function 
in OSD menu and adjust (by increment or decrement numbers) until those bars disappear. 
3.  Move to “Phase” function in OSD menu again and adjust the monitor screen to its most clear display. 
4.  Click “No” on “Shut Down Windows” and back to the normal PC operating environment. 
PROBLEM    There is no picture on LCD Monitor 
If there’s no picture on the LCD Monitor, please perform the following steps: 
1.  Make sure the power indicator on the LCD Monitor is ON, all connections are secured, and the system is running on 
the correct timing.    Refer to Chapter 3 for information on timing. 
2.  Turn off the LCD Monitor and then turn it back on again. If there is still no picture, press the Adjustment Control 
button several times.     
3.  If step 2 doesn’t work, connect your PC system to another external CRT.    If your PC system Functions properly with 
a CRT Monitor but it does not function with the LCD Monitor, the output timing of the VGA card may be out of the 
LCD’s synchronous range.    Please change to an alternative mode listed in the Standard Timing Table or replace the 
VGA card, and then repeat steps 1 and 2.     
PROBLEM    There is no picture on LCD Monitor   
If you have chosen an output timing that is outside of the LCD Monitor’s synchronous range (Horizontal: 24 ~ 80 KHz 
and Vertical: 49 ~ 75 Hz), the OSD will display a “Out of Range” message. Choose a mode that is supported by your LCD 
Monitor. 
Also, if the signal cable is not connected to LCD monitor at all or properly, the monitor screen will display a message “No 
Input Signal
”.