Panasonic BT-3DL2550E User Manual

Page of 64
34
Main Menu 
(continued)
CALIBRATION
Select CALIBRATION in the “SYSTEM CONFIG” menu to open the following menus.
*1 “EXECUTING” is displayed during “AUTO CALIBRATION” and “COMPLETE” appears when calibration ends. 
“INCOMPLETE” appears if calibration could not be completed. 
*2 When “RESET” ends, “COMPLETE” appears.
1. Press [
,
] in the “SYSTEM CONFIG” menu, 
select the [CALIBRATION] submenu and press 
[ENTER].
2. Press [
,
], select the [AUTO CALIBRATION] 
submenu and press [ENTER].
3. Select “YES” and press [ENTER]. 
This starts calibration.
xxxxxxxx indicates that one of the following 
messages with the meaning listed below appears.
EXECUTING: Operation in progress
COMPLETE: Operation completed
INCOMPLETE: Operation did not complete.
(Check RS-232C cable connection.)
1. Press [
,
] in the “SYSTEM CONFIG” menu, 
select the [CALIBRATION] submenu and press 
[ENTER].
2. Press [
,
], select the [RESET] submenu and 
press [ENTER].
3. Select “YES” and press [ENTER].
This resets the setting of this monitor.
xxxxxxxx indicates that the following message with 
the meaning listed below appears.
COMPLETE: Operation completed
Sub menu
Setting
Description
AUTO CALIBRATION 
*1
Connect a CA-210 color analyzer and use this submenu to make a 
calibration. 
Select “AUTO CALIBRATION” and select “YES” in the 
confirmation screen that appears to start calibration. 
RESET 
*2
Returns calibration data to their factory defaults. 
Select “RESET” and select “YES” in the confirmation screen that 
appears to return calibrated values to their factory defaults. 
Performing AUTO CALIBRATION
[AUTO CALIBRATION]
[AUTO CALIBRATION]
RESET operation
[RESET]
[RESET]