Planar EL320.256-FD7 User Manual

Page of 18
 
EL320.256-FD7 Operations Manual (020-0353-00A) 
Table 4. Timing Characteristics. 
Description Min 
Max 
Unit 
Note 
T1 Vertical Front Porch 
60 
 
µs 
T2 VS HIGH/LOW time 
 
tVCLK 
T3 Vertical Blank 
40 
 
µs 
 
T4 Vertical Period 
 
256 
 
tHS 
 
VS frequency 
 
120 
Hz 
 
Description Min 
Typ 
Unit 
Note 
T5 HS setup to VS 
 
 
µs 
T6 HS hold from VS 
 
µs 
 
T7 HS Low Time 
 
tVCLK 
 
T8 HS High Time 
320 
320 
tVCLK 
T9 HS period (tHS) 
19 
 
µs 
 
 
 
Notes: 
1. This time is needed to display the last row and to initiate the following  
    frame. 
2. Only rising edge is used. 
3. 2 tVCLK minimum 
4. The number of VCLK pulses during HS high time must be even. 
    Video clock VCLK must be kept running continuously. 
Setup and Hold Timing 
 
Figure 4. Setup and Hold Timing. 
 
Table 5. Setup and Hold Timing. 
Symbol Description 
Min 
Max 
tSU 
HS, VID, TVID setup to VCLK 
8ns 
 
tHOLD 
HS, VID, TVID hold from VCLK 
8ns 
 
tWL 
VCLK low width 
16ns 
 
tWH 
VCLK high width 
16ns 
 
tVCLK VCLK 
period 
40ns 
 
 
VCLK frequency 
 
25 MHz