Planar EL320.256-FD7 User Manual

Page of 18
 
EL320.256-FD7 Operations Manual (020-0353-00A) 
12 
 
Fig 5. Viewing Area Characteristics in mm. 
 
Installation and Handling 
EL320.256–FD7 should be mounted using the four M3 corner standoffs. It is 
recommended to use also the center nut in the mounting if the vibration or 
shock stress is severe.  
Before touching the display, necessary precaution must be taken to prevent  
application of static charges on the display from the operator or tools. 
The display is made of glass material and should be handled with proper care. 
Do not drop the display or allow hard objects to strike its surface.  
NOTE: For trouble-free data transfer a maximum cable length of 300  mm (12 
in.) from data transmitter to display input connector is recommended.  If 
longer cables up to 2 m ( 80 in.) length are needed, a serial resistor  of  appr. 
100 
Ω could be placed at each of the four signal line outputs of the 
transmitter in order to lower signal reflections.