Planar LC12 User Manual

Page of 24
Title:  Product Specification: LC12 High-Bright Monitor 
Page 5 of 24 
Document Number: 023-0284-01 
 
          Revision:  A 
2.0 Basic Construction 
2.1       Weight 
Monitor weight does not exceed 5 Kgs (11 lbs). 
2.2       Mechanical Mounting Requirements 
Per Planar Mechanical Outline drawing 074-0666-01 
2.3       Monitor Electronics 
Electronic components requiring heat sinks are installed independent of the Monitor enclosure.  
That is, its sheet metal chassis is not used as a heat sink for any electronic component. 
2.4       Cooling Fan  
 
 
Cooling fans are installed to maintain appropriate internal operating temperatures when the 
Monitor is subjected to its operating environment of Section 3. Forced air convection is used to 
cool the LCD Panel (front and back). 
2.5       Vandal Glass 
The Monitor is designed to operate with a vandal glass 289 mm x212 mm x 10 mm in place. This 
vandal glass in not provided with the Monitor. 
2.6       Air Filtration 
An air filter mesh is included to prevent ingress of insects and ensure continual flow of cooling air 
within the Monitor.  The air filter mesh is externally accessible for cleaning.  
2.7       Connectors 
There are two (2) connectors supplied as an integral part of the Monitor.   
2.7.1       
Video Signal Connector 
The Monitor unit includes a chassis mounted 15-pin female mini D-Shell connector 
(AMP 748390-5 or equivalent) with socket contacts at the rear of the Monitor.  It is 
shielded for electromagnetic interference (EMI) purposes.  Refer to Section 4.1 for 
electrical connections. 
2.7.2       
DC Power Input Connector  
The DC power input connector is a chassis mounted 2-pin "MAT?N?LOK" style 
connector (AMP 1-480699-0 or equivalent) with pin contacts at the rear of the 
Monitor.  Connections are insulated to insure no accidental contact.