Marantz PD4293D User Manual

Page of 64
47
36. INVERSE Set
Function
The external control equipment sets the INVERSE (inverse of image brightness)
and the WHITE of the plasma monitor.
Transmission Data
DFH
80H
 60H  C7H 03H
DATA00 DATA01 DATA02 CKS
DATA00 : INVERSE/WHITE
00H: No operation
01H: ON(INVERSE)
02H: OFF
03H:  WHITE
DATA01 : WORKING TIME
00H: ON
01H: 03M (minutes)
02H: 06M (minutes)
FFH: 12H (hours) and 45M (minutes)
DATA02 : WAITING TIME
01H: 03M (minutes)
02H: 06M (minutes)
FFH: 12H (hours) and 45M (minutes)
ACK
3FH
60H
80H
C7H
00H
CKS
NOTE: The WORKING TIME and the WAITING TIME can be set in
units of 3 minutes.
Example: 03H=9 minutes
1EH=1 hour and 30 minutes
37. SCREEN WIPER Set
Function
The external control equipment sets the SCREEN WIPER of the plasma monitor.
Transmission Data
DFH
 80H  60H C8H
04H
DATA00 to
DATA03 CKS
DATA00 : SCREEN WIPER
00H: No operation
01H: ON
02H: OFF
DATA01 : WORKING TIME
00H: ON
01H: 03M (minutes)
02H: 06M (minutes)
FFH: 12H (hours) and 45M (minutes)
DATA02 : WAITING TIME
01H: 03M (minutes)
02H: 06M (minutes)
FFH: 12H (hours) and 45M (minutes)
DATA03 : SPEED
01H: 1
05H: 5
ACK
3FH
60H
80H
C8H
00H
CKS
NOTE: The WORKING TIME and the WAITING TIME can be set in
units of 3 minutes.
Example: 03H=9 minutes
1EH=1 hour and 30 minutes
38. RESET
Function
The external control equipment resets the user adjustment of the plasma
monitor.
Transmission Data
1FH
80H
60H
54H
00H
CKS
ACK
3FH
60H
80H
54H
00H
CKS
39. Audio Select Set
Function
The external control equipment sets combinations of audio and video inputs
for the plasma monitor.
Transmission Data
DFH
80H
60H
70H
02H
DATA00 DATA01 CKS
DATA00: AUDIO INPUT
01H: AUDIO 1
02H: AUDIO 2
03H: AUDIO 3
DATA01: VISUAL INPUT
01H: Video 1
02H: Video 2
03H: Video 3
05H:HD (HD1 or DTV or DTV1)
06H: HD2 (DTV2)
07H: RGB 1/ PC 1
08H: RGB 2/ PC 2
0CH: RGB 3/ PC 3
ACK
The plasma monitor returns the following ACK when the input is switched.
3FH
60H
80H
70H
00H
CKS
* The plasma monitor returns “Not Available” when selecting the
video input same as the one set at one of the AUDIO 1 to 3.
Example:
The plasma monitor returns “Not Available” when selecting the
VIDEO1 for AUDIO2 or VIDEO3 after VIDEO1 has been set to
AUDIO1.