Omega 3200 User Manual

Page of 26
M-4271/0707, pg. 10 of 26 
c)  Connecting The 6 Pin Mini Din Connector & FMA 3000C Cable 
 
The two mating connectors should be pushed together and the pigtail 
leads wired as follows: 
 
Connecting To The Integrated 6 Pin Connector Using A FMA 3000C Cable  
 
 
 
The RED wire should be connected to the Positive of the power source.  
 
The BLACK wire  should be connected to the Negative (Ground) of the 
power source. 
 
The ORANGE wire  provides the signal output and should be connected to 
the positive terminal of the display, data acquisition system or voltmeter. 
 
The BROWN wire  is the signal negative (ground) and should be 
connected to the negative (Ground) terminal of the display, data 
acquisition system or voltmeter. 
 
The YELLOW wire  provides the input signal and should be connected to 
the positive terminal of the voltage source. The (0-5VDC) voltage control 
signal should be supplied from a low impedance source.  
 
The GREEN wire  is the input signal negative (ground) and should be 
connected to the negative (Ground) terminal of the voltage source. 
 
The wire colors above describe the pigtail leads of the FMA 3000C cable 
assembly and may not correspond with the internal wiring of your flow 
sensor. 
 
 
Caution: Avoid high voltage static discharges to the input signal 
connection. Do not short the input/output signal wires or allow 
them to contact the power wires at any time. DAMAGE WILL 
RESULT!