8.2.34 SMART (B0h) 
 
 
 
Individual  SMART  commands  are  identified  by  the  value  placed  in  the  Feature  resister.  Below  depicts  these 
Feature register values. 
 
Table 8-14 SMART Feature Registers Values 
 
Feature Value
 
Command
 
D0h 
SMART READ DATA 
D1h 
Obsolete (SMART Read Threshold) 
D2h 
SMART ENABLE/DISABLE  ATTRIBUTE AUTOSAVE 
D3h 
Obsolete (SMART Save Attribute Value) 
D4h 
SMART EXECUTE OFF-LINE IMMEDIATE 
D5h 
SMART READ LOG SECTOR 
D6h 
SMART WRITE LOG SECTOR 
D7h 
Obsolete 
D8h 
SMART ENABLE OPERATIONS 
D9h 
SMART DISABLE OPERATIONS 
DAh 
SMART RETURN STATUS 
DBh 
Obsolete (Enable/Disable Auto Offline Scan) 
DCh-DDh 
Reserved 
DEh 
Reserved 
DFh 
Reserved 
 
 
 
 
8.2.34.1         Smart disable operations (D9h) 
 
 
 
This  command  disables  all  SMART  capabilities  within  the  device  including  any  timer  and  event  count 
functions  related  to  this  feature.  After  receipt  of this  command  the  device  shall  disable  all  SMART  operations. 
SMART  data  shall  no  longer  be  monitored  or  saved  by  the  device.  The  state  of  SMART  (either  enabled  or 
disabled) shall be preserved by the device across power cycles. 
 
After  receipt  of  this  command  by the  device,  all  other  SMART  commands  (including  SMART  DISABLE 
OPERATIONS  commands),  with  the  exception  of  SMART  ENABLE  OPERATIONS,  are  disabled  and 
invalid and shall be command aborted by the device. 
 
8.2.34.2         Smart enable/disable attribute auto-save (D2h) 
 
 
 
This  command  enables  and  disables  the  optional  attribute  auto-save  feature  of  the  device.  Depending  upon 
the  implementation,  this  command  may  either  allow  the  device,  after  some  vendor  specified  event,  to 
automatically  save  its  updated  attribute  values  to  non-volatile  memory;  or  this  command  may  cause  the  auto- 
save  feature  to  be  disabled.  The  state  of  the  attribute  auto-save  feature  (either  enabled  or  disabled),  shall  be 
preserved by the device across power cycles. 
 
A  value  of  zero  written  by the  host  into  the  device’s  Sector  Count  register  before  issuing  this  command  shall 
cause  this  feature  to  be  disabled.  Disabling  this  feature  does  not  preclude  the  device  from  saving  SMART 
data  to  non-volatile  memory  during  some  other  normal  operation  such  as  during  a  power-on  sequence  or 
during an error recovery sequence.