Maxtor 10K III User Manual

Page of 284
 SCSI Description
5-42
Maxtor Atlas 10K III
<
('!' !"#8 1 ( C "* +
Table 5-53 lists the mode pages that are supported by the drive. An initiator can 
change these pages by supplying them, with the desired changes included, in the 
MODE SELECT command’s data-out buffer transfer.
The initiator should first use a MODE SENSE command to read the appropriate pages 
and leave non-changeable values as read when the initiator subsequently writes the 
changeable pages with the MODE SELECT command. If a non-changeable field 
contains an invalid value, the drive returns a CHECK CONDITION status.
Table 5-53   
Initiator-Changeable Mode Pages
NOTES:
1. This page is not supported by the SCSI-1/CCS Operating Mode. 
2. The Notch and Partition page is changeable but NOT savable.
3. XOR is currently disabled and page is not changeable.
#0+,
#09
&)*+
*G5(
00h
Unit Attention Control Page
Unit Attention report-
ing (enables or dis-
ables)
 4
01h
Read-Write Error Recovery Page
Medium Access Error 
recovery and report-
ing procedures for
READ and WRITE 
commands
12
02h
Disconnect-Reconnect Page
Bus behavior during 
data transfers
 16
07h
1
Verify Error Recovery Page
Medium Access Error 
recovery and report-
ing procedures for the
VERIFY command
 12
08h
1
Caching Page
 Cache policy
20
0Ah
1
Control Mode Page
Command processing 
policy
 12
0Ch
Notch and Partition Page
2
Drive geometry re-
porting
24
10h
XOR Control Page
Controls XOR operat-
ing parameters 
24
19h
Port Control Page
Defines port control 
parameters
 8
1Ah
Power Condition Page
Enable and set time 
intervals for Idle and 
Standby modes
 12
1Ch
1
Information Exceptions Control 
Page and operations of specific 
informational exception condi-
tions.
Defines methods to 
control reporting 
12
39h
Maxtor-Unique Page
 22