SCSI Description
Maxtor Atlas 10K III
5-59
Table 5-75   
Notch and Partition Page-Field Descriptions (Page 0Ch)
"&*2,
"?2
<2
"()**+
PS
0
Parameters Savable. This bit is only used with the MODE SENSE com-
mand. The returned value of 0 indicates that the target is not capable 
of saving this page in a non-volatile vendor specific location
 This bit is 
reserved with the MODE SELECT command.
ND
1
Notched (banded) Drive. A value of 0 indicates that the drive is not 
notched and that all other parameters in this page are returned as 0. 
The default value of 1 indicates that the device is notched. For each 
supported active notch value, this page defines the starting and ending 
boundaries of the notch.
 LPN
0
Logical or Physical Notch. The default value of 0 indicates that the 
boundaries of the notch are based on the physical parameters of the 
logical unit. The cylinder is considered most significant and the head 
least significant. 
A value of 1 indicates that the notch boundaries are based on logical 
blocks of the logical unit.
MaxNotch 24
This field indicates the maximum number of notches supported by the 
logical unit. The value cannot be changed.
Active 
Notch
0
The Active Notch field indicates the notch referenced by this, and sub-
sequent MODE SELECT and MODE SENSE commands. The value in 
this field can be changed by a later MODE SELECT command. The val-
ue of the active notch must be = 0 and = 24. An active notch of 0 
indicates that this and subsequent MODE SELECT and MODE SENSE 
commands refer to the parameters that apply across all notches.
Starting 
Boundary
000000h,00h
This field indicates the beginning of the active notch or, if the active 
notch is 0, the beginning boundary of the logical unit. If the LPN value 
is 1, the starting boundary is a Logical Block Address.
If the LPN value is 0, the three most significant bytes designate the 
starting cylinder number and the least significant byte is the starting 
head number. This field is unchangeable. When used with the MODE 
SELECT command, this field is ignored.
Ending 
Boundary
18GB: 
792D01H
792DH = 31021 which refers to the ending cylinder, 01H is the end-
ing head number
36GB: 
792D03H
792DH = 31021 which refers to the ending cylinder, 03H is the end-
ing head number
73GB: 
792D07H
792DH = 31021 which refers to the ending cylinder, 07H is the end-
ing head number
Pages 
Notched
00000000b,
00000000b,
00000000b,
00000000b,
00000000b,
00000000b,
00010000b,
00001000b
This is a 64-bit bitmap that indicates which MODE command pages 
contain parameters that may be different for different notches. The 
most significant bit (MSB) corresponds to Page 3Fh (Vendor-Unique 
Caching Page), and the least significant bit (LSB) corresponds to Page 
00h
(Unit Attention Control Page).
If a bit is 1, the corresponding mode page contains parameters that 
may be different for different notches.
If a bit is 0, the corresponding mode page contains parameters that are 
constant for all notches.
The value of 1 in bits 3 and 12 indicates that Page 03h and 0Ch contain 