Maxtor 10K III User Manual

Page of 284
SCSI Description
Maxtor Atlas 10K III
5-63
Table 5-79   
Power Condition Page-Field Descriptions (Page 1Ah)
&*2,
"?2
<2
"()**+
PS
0
Parameters Savable. This bit is only used with the MODE SENSE com-
mand. A returned value of 1 indicates that the target is capable of saving 
the page in a non-volatile, vendor-specific location. The bit is reserved 
with the MODE SELECT command.
IdlEnb
0
Enable Idle Timer. This is a lower power consumption state of the drive. 
A media access command waits for an approximately one second transi-
tion time delay from the IDLE to the ACTIVE state. 
SbyEnb
0
Enable Standby Timer. Any media access command waits for an approxi-
mately 10 second transition time delay from the STANDBY to the ACTIVE 
state.
Idle Timer
0
The Idle Timer specifies the time, in 100-millisecond increments, before 
entering the IDLE state after the last media access command. The IdlEnb 
field must be set to 1. The internal minimum value for this field is 60 sec-
onds.
Standby 
Timer
0
The Standby Timer specifies the time, in 100-millisecond increments, be-
fore entering the Standby state after the last media access command. The 
SbyEnb field must be set to 1. The internal minimum value for this field is 
15 minutes.