Maxtor 10K III User Manual

Page of 284
 SCSI Description
5-68
Maxtor Atlas 10K III
Table 5-84   
Maxtor-Unique Page-Field Descriptions (Page 39h)
&*2,
"?2
"()**+
PS
1
Parameters Savable. This bit is only used with the MODE SENSE command. 
A returned value of 1 indicates that the disk drive is capable of saving the 
page in a non-volatile, vendor-specific location. The bit is RESERVED with 
a MODE SELECT command.
Wait SpinUp 
Enable
0
When this field = 0, the disk drive spins up upon power on. When this field 
= 1, the disk drive performs a Wait/Spin.
Enable Error 
Logging
0
When this field = 0, Error Logging is disabled. 
When this field = 1, Error Logging is enabled.
Disable 
Parity Check
0
When this field = 0, Parity Checking is enabled. 
When this field = 1, Parity Checking is disabled.
Realloca-
tion Uncor-
rected 
Errors
0
When this field = 0, reallocation of blocks that have uncorrectable read er-
rors does not take place
When this field = 1, a block that encounters an uncorrectable read error will 
be marked for pending reallocation. The block in error remains “as is” for a 
possible recovery on a future access. If a subsequent successful read or 
write (with readback / compare) occur, the pending reallocation will be de-
ferred. However, it will be “remembered” that an unrecoverable read oc-
curred at one time, and if a second unrecoverable read occurs, the block will 
be reallocated on the next successful access. Also, if a subsequent unsuc-
cessful write occurs on a block marked for pending reallocation, the block 
will be reallocated.
Enable Fill 
Data Pattern
1
When this field = 0, the disk drive ignores any information in Byte 2 of the 
FORMAT UNIT command. Note that if the setting in Byte 2 of FORMAT 
UNIT is “0”, the disk drive will interpret that setting as “1.”
When this field = 1, the disk drive writes the data pattern that is specified 
in Byte 2 of the FORMAT UNIT command into every user-accessible block 
when the disk drive executes a FORMAT UNIT command.
Disable 
SCAM
(Parallel)
When this field = 0, SCAM is enabled. When this field = 1, SCAM features 
are disabled.
Disable Unit 
Att’n
0
When this field = 0, a UNIT ATTENTION condition exists following power 
on or a reset caused by either a BUS DEVICE RESET message or a hard reset 
condition.
When this field = 1, the disk drive will not issue a CHECK CONDITION sta-
tus with the UNIT ATTENTION sense key on the first command following a 
reset. The disk drive will execute the first command issued after a reset con-
dition.
SSSIE
0
Software Selectable SCSI ID Enable. When this field = 0, the disk drive’s 
SCSI ID is determined via the disk drive’s hardware ID select jumper set-
tings.
When this field = 1, the disk drive’s SCSI ID setting is determined by the 
value set in the Software Selectable SCSI ID field (Byte 3, bits 0 – 3).
Disable 
Auto WRITE
0
When this field = 0, the Auto WRITE function is enabled. 
When this field = 1, the Auto WRITE function is disabled.
Disable 
Auto READ
0
When this field = 0, the Auto WRITE function is enabled. 
When this field = 1, the Auto WRITE function is disabled.
Use Three 
Bits for 
Delay
0
When this field = 0, Delay Spin is not enabled. 
When this field = 1, and Staggered Spin Delay (Bytes 6 & 7) is enabled, the 
three lower bits of the disk drive’s SCSI ID are used for the multiplier to de-
termine the length of the delay. When only three bits are used, disk drives 
0 through 7 and drives 8 through 15 have the same corresponding delays 
since the fourth bit is not used (disk drive 0 has the same delay as disk drive 
8, disk drive 1 has the same delay as disk drive 9, and so on).