SCSI Description
Maxtor Atlas 10K III
5-75
<6
263 "%% (* 213
The MODE SENSE (6) command allows the initiator to read the drive's sector 
descriptor and mode pages. The MODE SENSE Command Descriptor Sector is 
shown in Table 5-89 and the data fields are described in Table 5-90. The Mode 
Parameter Header is shown in Table 5-91 and the data fields are described in 
Table 5-92.
Table 5-89   
MODE SENSE (6) Command Descriptor Block-Data Format
Table 5-90   
MODE SENSE Command-Field Descriptions
Table 5-91   
Mode Parameter Header (6 Byte)-Data Format
*
5
>
'
%
$
0
Operation Code (1Ah)
1
Reserved
DBD
Reserved
2 PC
Page 
Code
3
Sub Page Code
4
Allocation Length
5
Control
"&*2,
"()**+
DBD
Disable Block Descriptor. When the value is 0, the drive returns its Block 
Descriptor followed by the requested page(s). When the value is 1, the drive 
returns only the requested pages.
PC
Page Control. Determines which type of page values are returned. These 
values are:
00b Current
01b Changeable
10b Default
11b Saved
Page Code
The Page Code field determines the pages to be returned to the initiator in 
the command's data-in buffer transfer. Refer to Table 5-53 and Table 5-93 
for a complete list of the Mode Pages (changeable and read-only). A Page 
Code of 3Fh causes all supported pages to be returned.
Bit
5
>
'
%
$
0
Mode Data Length
1
Medium Type
2
Device-Specific Parameter
3
Block Descriptor Length