 SCSI Description
5-110
Maxtor Atlas 10K III
<
"%% (* 2 <13
The READ CAPACITY command reports formatted capacity and track-boundary 
information. The data format and field descriptions are shown in Table 5-131 and 
Table 5-132 respectively.
Table 5-131   
READ CAPACITY Command-Data Format
Table 5-132   
READ CAPACITY Command-Field Descriptions
Table 5-133 shows the READ CAPACITY Returned Data - Data Format that will 
be sent during the data-in buffer transfer for the command. Refer to the PMI 
description in Table 5-132 for a description of these data fields.
Table 5-133   
READ CAPACITY Returned Data-Data Format
*
5
>
'
%
$
0
Operation Code (25h)
1
Reserved
RelAdr
2 - 5
Logical Block Address 
6 - 7
Reserved
8
Reserved
PMI
9
Control
&*2,
"()**+
RelAdr
Relative Addressing is not supported by the drive; the field must 
be 0.
Logical Block Address
Used in conjunction with the PMI bit. Must be 0 when the PMI bit 
is 0.
PMI
Partial Media Indicator. When the value in the field is 0, the Re-
turned Logical Block Address (Table 5-133) is that of the last log-
ical sector of the logical unit.
When the value is 1, the Returned Logical Block Address is that 
of the last sector on the same cylinder as the Logical Block Ad-
dress supplied in the Command Descriptor Block's LBA field. That 
is, the Returned Logical Block Address is that of the Logical Block 
Address before a substantial delay in data transfer will be encoun-
tered).
In either case, Block Length in Bytes (Table 5-133) is the unit's 
logical sector size, as determined by the Block Length field in the 
Mode parameter Block Descriptor.
*
5
>
'
%
$
0 - 3
Returned Logical Block Address
4 - 7
Block Length in Bytes