Maxtor 10K III User Manual

Page of 284
SCSI Description
Maxtor Atlas 10K III
5-115
Table 5-141   
READ DEFECT DATA (12) Command-Field Description
1
 All in-line spared blocks do not have an associated LBA, and, therefore, will not be 
seen in Logical Block Format.
Table 5-142 shows the Block Format returned when the Defect List Format is 000b.
Table 5-142   
Defect Descriptor-Block Format
Table 5-143 shows the Defective Bytes From Index Format when the Defect List 
Format is 100b or the Physical Sector Format when the Defect List Format is 101b.
Table 5-143   
Defect Descriptor-Bytes From Index Format, or Physical Sector Format
&*2,
"()**+
PList
When the value is 0, the returned data does not include the Primary Defect List.
When the value is 1, the returned data includes the Primary Defect List. The defects 
are returned in ascending order.
GList
When the value is 0, the returned data does not include the Grown Defect List.
When the value is 1, the returned data includes the Grown Defect List. The defects 
are returned in order of occurrence.
When both PList and GList are set to 1, the Primary Defect List and the Grown Defect 
List are returned. The Plist is returned followed by the Glist (the lists are not merged). 
When both are set to 0, only the Defect List Header (Table 5-144) is reported to the 
initiator.
Defect List 
Format
This field specifies the format in which the defect descriptors are to be returned. The 
supported formats are:
000b
Block Format (Table 5-142).
100b
Bytes from the Index (Table 5-143). The data returned from this 
mode does not include defects outside normal user space.
101b
Physical Sector Format (Table 5-143). Default format. The de-
fects returned from this mode do not include defects outside 
normal user space.
110b
Vendor-Unique Format. This format is valid only for the READ 
DEFECT DATA commands. The data returned from this mode 
does not include defects outside normal user space. Note that 
the vendor-unique format is proprietary in nature and thus is not 
documented in this Product Manual.
*
5
>
'
%
$
0 - 3
Defective Block Address
*
5
>
'
%
$
0 - 2
Cylinder Number of Defect
3
Head Number of Defect
4 - 7
Defective Bytes From Index / Defective Sector Number