The SEND DIAGNOSTIC command sends a diagnostic page to the drive. Refer to 
the RECEIVE DIAGNOSTICS RESULTS command for a description of the 
diagnostic pages and the use of the diagnostic commands. The Supported Diagnostic 
Page List (Table 5-199) and Translate Page List (Table 5-200) can be sent with this 
command. Table 5-197 shows the SEND DIAGNOSTIC CDB data format and 
Table 5-198 shows the field descriptions. 
Table 5-197   
SEND DIAGNOSTIC Command Descriptor Block-Data Format
Table 5-198   
SEND DIAGNOSTIC Command-Field Descriptions
*
5
>
'
%
$
0
Operation Code (1Dh)
1
Function
PF
Rsvd
Self
Test
DevOnl
UnitOfl
2
Reserved
3 - 4
Parameter List Length
5
Control
&*2,
"()**+
Function
When the SelfTest bit is set to one, the Function code field is 000b. When the Self-
Test bit is cleared to zero, the content of the Function code field is specified as fol-
lows:
000b: Value to be used when the SelfTest bit is set to one or if the SEND DIAGNOS-
TIC command is not invoking one of the other self-test function codes (for example, 
Translate Address page)
001b: Background short self-test. The device server will start its short self-test rou-
tine in the background mode.
010b: Background extended self test. The device server will start its extended self-
test routine in the background mode.
011b: Reserved
100b: Abort background self-test. Abort the current self-test running in background 
mode. This value is only valid if a previous SEND DIAGNOSTIC command specified 
a Background self-test function and that function has not completed. If either of 
these conditions is not true, then the device server will respond by returning a 
CHECK CONDITION with a sense key of NOT READY and an additional sense code 
of LOGICAL UNIT NOT READY, SELF-TEST IN PROGRESS.
101b: Foreground short self-test. The device server will start its short self-test rou-
tine in the foreground mode
110b: Foreground extended self-test. The device server will start its extended self-
test routine in the foreground mode
111b: Reserved
PF
Page Format. When the PF bit is 1, the parameters that follow conform to the Sup-
ported Diagnostic Page List (Table 5-199) or the Translate Address Page 
(Table 5-200).
SelfTest is ignored when PF = 1.
The PF bit must be 1 if Parameter List Length is not 0.