Specifications
4-6
Maxtor Atlas 10K III
<
#'A "?# '++'& !'"(
Table 4-5 lists the drive power dissipation and the corresponding currents for the 
various modes of operation of the Maxtor Atlas 10K III hard disk drive.
Table 4-5   
Power Dissipation in Various Modes (Low-Profile Drives)
1. Current is RMS except for Startup. Startup current is the peak (> 10 ms) 
current required during spindle startup. Current measurements do not 
include power required for SCSI termination.
2. Idle mode is in effect when the drive is not reading, writing, seeking, or 
executing any commands. A portion of the R/W circuitry is powered 
down, the motor is up to speed and the Drive Ready condition exists.The 
actuator resides on the last track accessed.
3. Random Seek + Read/Write measured at 100% random 2KB R/W, Q=4.
4. Maximum Average Current is defined as mean current plus 3 Standard 
Deviations.
5. Power requirements reflect nominal values for +12V and +5V power 
supplies.
6. Standby mode is in effect when the motor is stopped, the actuator parked, 
and all electronics except the interface control is in low power state. Standby 
will occur after a programmable time-out since last host access occurs. Drive 
Ready and Seek Complete status exist. The Standby mode will not be in 
effect upon receipt of a command which requires disk access or upon receipt 
of a spin-up command.
1, 4
Startup
 
peak
1
2.2
2.2
2.2
0.9
0.9
0.9
30.9
30.9
30.9
Idle
2
0.63
0.63
0.63
0.46
0.46
0.46
10.2
10.2
10.2
Random Seek 
+ Read/
Write
3
0.97
0.97
0.97
0.79
0.79
0.79
15.6
15.6
15.6
100% 
Random Seek
 
(No R/W)
1.14
1.14
1.14
0.52
0.52
0.52
16.3
16.3
16.3
Standby
6
0.48
0.48
0.48
.305
.305
.305
7.26
7.26
7.26