Sony SDX-800V/R User Manual

Page of 206
MODE SELECT 
6.Command Specification
SONY AIT-3Ex drive SDX-800V series Ver.1.1 
 
6-51 
6.7.8. Append Partition (32h) (This mode page is NOT 
supported) 
The Append Partition Command is available in the AIT mode. The Append Partition Command takes effect if the 
current partition is the last partition. When the command is issued in the last partition and then creates a new 
partition. If the command is issued in any other partition, SDX-800V will return the CHECK CONDITION status 
(83h/97h Current Partition is no the last partition).   
Table 6-47: Append Partition Page 
Bit 
Byte 
7 6 5 4 3 2 1 0 
Reserved 
Page Code (32h) 
Page Length (8) 
Reserved 
Reserved 
Reserved PSUM Reserved 
Reserved 
Reserved Partition 
units 
Reserved 
(MSB) 
Partition Size Descriptor 
 
 
 
(LSB)
PSUM 
The Partition Size Unit of Measured field defines the units in which the Partition Size value selects the partition size. 
Code Description 
Support 
00b 
bytes (unit of one) 
Not Support 
01b kilobytes 
(10
3
 bytes) 
Not Support 
10b Megabytes 
(10
bytes) Optional 
11b 10 
(PARTITION UNITS)
 bytes 
Optional 
Partition units 
This field defines the size of the partition size descriptors when the PSUM field is set to 11b. A value of n in the 
PARTITION UNITS field shall define the units of the partition size descriptors as 10
n
 bytes. 
SDX-800V Supports following combinations. 
PSUM Partition 
Units 
11b 
  1001b : 10
9
 byte (AIT-3Ex Mode) 
If another value is set these fields a CHECK CONDITION status is returned with an ILLEGAL REQUEST sense key 
set. 
Partition Size Descriptor 
Partition size in megabytes, in binary notation. Bytes 8, 9: Partition Size Descriptor. For a Mode Sense Command, 
the value in this field is invalid unless the Mode Sense Command follows a successful Mode Select Command Page 
32. Therefore, on power-up without a Mode Select Page 32h, the Current Page 32h Partition Size Descriptor should 
be set to the default value of 00 00. There is no relation between this field and the IDP bit in the parameter block of 
Mode Select Page 11h.