7.Drive Diagnostics 
7-4 
SONY AIT-3Ex drive SDX-800V series Ver.1.1 
 Sequence Test 
00 
Reset Sequence (61, 63, 71,72, 77-79, 80, 81, 30) 
 
Mechanism Controller Kernel Test 
20 
Mechanism Controller Microprocessor Test 
 
Main Processor Kernel Test 
61 
Main Processor ROM checksum 
62 
Main Processor Destructive RAM Test 
 
Drive Test 
71 
Buffer RAM Test 
PH 
79 
Data Compression Functions and DMA Line Test 
PH 
80 
Internal Message Bus Test 
PH 
 
7.2.5.   RECEIVE DIAGNOSTIC RESULT command 
Whenever a diagnostic test is executed, the drive automatically prepares a diagnostic test result that can be returned 
to the host computer when a RECEIVE DIAGNOSTIC RESULT command is issued. 
If the PF bit in the SEND DIAGNOSTIC command was sent to one, the diagnostic test result will be preceded by a 
four byte header which will be of the form: 
 
Table 7-3: RECEIVE DIAGNOSTIC RESULT - SCSI-2 Header 
Bit 
Byte 
7 6 5 4 3 2 1 0 
Page Code (81h) 
Reserved 
(MSB) 
Page Length (00 05h) 
 
  
(LSB) 
Regardless of the PF bit in the SEND DIAGNOSTIC command, the five bytes of diagnostic test result information will 
be of the form: 
Table 7-4: RECEIVE DIAGNOSTIC RESULT 
Bit 
Byte 
7 6 5 4 3 2 1 0 
Reset 
Error 
Time 
Re-Sync 
Reserved Error 
Set 
Error Code 
Result A 
Result B 
Diagnostic Test Number 
Reset error: This bit is set when an error occurs during power-on self-test. 
Time Re-Sync: This bit indicates that the time stamp saved with the error log has no relation to that of the previous 
entry. It is only set by the logging routine within the data buffer as an error is logged.