Sony SDX-800V/R User Manual

Page of 206
13. Appendix F
 
SONY AIT-3Ex drive SDX-800V series Ver.1.1 
13-3
 (ii)How to initialize a WORM cartridge to AIT Native mode. 
 1Partition 
 
 
 
 
 
 
AIT=1, DEVICE=1, ABS=1, SysLogAlive=11, Span=0Ah 
 
 
 
Set IDP bit to 1. Additional Partition=0.  
13.5. How to handle the WORM cartridge in the drive 
1.  DATA READ: There is no restriction when reading data in WORM mode.  
2.  DATA WRITE: Any attempt to overwrite existing data will be rejected with a Check Condition status and 
sense data. 
●  Write Projected Error:  07-27-00-07 (Sense Key, ASC, ASCQ, Run-time-error) 
●  Append Position Error: 03-27-04-f7 
The AIT WORM drive will allow write operations when: 
(1)  Append Write Operation is allowed only at End-Of-Data (EOD) area. Prior to an Append Write Operation, 
several commands can be used to position the drive at EOD area: 
●  Space to EOD (space code 3) 
●  Space to last record (could be a block, File-mark, Set-mark) 
●  Locate to last block 
●  Read until EOD 
For example: 
 
 
 
 
 
 
 
 
 
No  
 Yes 
 
 
 
Mode Sense (Page 31h) 
Mode Select (Page 31h) 
Mode Select (Page 11h) 
Space EOD 
Write 
Write End
END