Sony SDX-800V/R User Manual

Page of 206
LOG SENSE 
6.Command Specification
SONY AIT-3Ex drive SDX-800V series Ver.1.1 
 
6-27 
All board revision number is 8 bytes long and has a following format: 
Table 6-27: All Board Revision Number Parameter Format 

Set revision 

Board revision 

Mechanism revision 

RF revision 
Each Mechanism Error Event is 24 bytes long and has following format: 
Table 6-28: Mechanism Error Event Format 
Byte offset  
Meaning 
0-3 
5-6 
Drum revolution minutes 
Last mc Command 
Error code 
Reserved 
 
6.6.10. Read and Write Frame Error Counter Page 
The Read and Write Error Counter Page has the following format. All fields in these logs are initialized to ZERO in 
the following circumstances: 
At Power On 
After a cassette loading 
After a user sends a request for initialization through Log Select 
After a SCSI Bus Reset 
Following configuration for error rate testing 
Table 6-29: Read and Write Frame Error Counter Page 
Bit 
Byte 
7 6 5 4 3 2 1 0 
Page Code (34h Write Frame Error Counters, 35h Read Frame Error Counters) 
Reserved 
(MSB) 
Page Length (88h) 
 
  
(LSB) 
Error Counter Descriptors 
Bit 
Byte 
7 6 5 4 3 2 1 0 
(MSB) Parameter 
Code 
 
  
(LSB) 
DU (0) 
DS (1) 
TSD (0)
ETC (0)
TMC (0) 
LBIN (0) 
LP (0) 
Parameter Length (4) 
(MSB) Parameter 
Value 
 
  
(LSB) 
Parameter Code: This identifies which parameter of data is being transferred. The following codes are supported for 
each Error Counter Page.