Sony SDX-800V/R User Manual

Page of 206
LOG SENSE 
6.Command Specification
SONY AIT-3Ex drive SDX-800V series Ver.1.1 
 
6-37 
6.6.14.  MIC Variable Length Information Page (Sony Unique) 
Page 3Eh is a variable length page. That is not defined by ANSI. This page is Sony Vendor Unique. 
Important NOTE:  
1.  Only one Parameter Code in Page 3Eh is transferred at a time.   
2.  Byte position 3 of Parameter Code in the Page 3Eh is Reserved. (Should be set to ZERO.) 
3.  Parameter Length for the contents of the Parameter Code in Page 3Eh is stored at the byte position 4 and 5. 
4.  The Page Length field in the Page Code indicates the total number of bytes that follow this byte. This value is 
independent of what is specified for the Allocation Length in the CDB. 
Table 6-35: MIC Variable Length Information Page 
Bit 
Byte 
7 6 5 4 3 2 1 0 
Page Code (3Eh) 
Reserved 
(MSB) 
Page Length (n-3) 
 
  
(LSB) 
 
Parameter Code 
Description 
0001h 
0002h 
User Volume Note 
User Partition Note for Partition 0 
 
(MSB) 
Parameter Code (0001h) 
 
 
(User Volume Note) 
(LSB) 
DU (0) 
DS (1) 
TSD (0)
ETC (0)
TMC (00) 
LBIN (1) 
LP (1) 
Reserved 
(MSB) 
User Data Length 
 
  
(LSB) 
(MSB) User 
Data 
 
  
(LSB) 
 
(MSB) 
Parameter Code (0002h) 
 
 
(User Partition Note for Partition #0) 
(LSB) 
DU (0) 
DS (1) 
TSD (0)
ETC (0)
TMC (00) 
LBIN (1) 
LP (1) 
Reserved 
(MSB) 
User Data Length 
 
  
(LSB) 
(MSB) User 
Data 
 
  
(LSB) 
Note:  
1.   If there is no Note data in MIC for the Parameter Code specified in the CDB a Check Condition status will be 
returned. 
2.   If the CDB allocation length is ZERO a Good status is always returned and there is no data phase.  
3.   If the CDB allocation length is non-ZERO and there is data in MIC for the Parameter Code data will be returned 
up to the size of the MIC data, as limited by the allocation length.  For example, if the CDB allocation length is 
0FFh and MIC data size for the Parameter Code is 020h 020h data will return.  If the CDB allocation length is 
010h and the MIC data size for the Parameter Code is 020h only 010h data will be returned.