SSD COMPANY LIMITED 637f User Manual

Page of 27
1
 
General Information
 
 
________________________________________________________________________________________________________________________________________________________________________________________________________________________  
16 
 
Product Manual  Type: 637f
 
07-02-10-01-E-V0505.doc
 
 
1.3 Range 
Data 
 
1.3.1  Insulation Concept  
COM1 
COM2 
Rem ote IN 
X10 
analog 
X10 
digital 
X40 
X30 
dep. Optionsmodule 
M1, M2, M3  
DC-bus 
brak - cirquit 
L1, L2, L3 
Us    DC 24 V 
power supply 
DC 24 V 
PE 
L1 
AC  
power - terminals 
double insulation VDE 0160 
Insulation of control voltage supply 
Required for safe separation (PELV): double insulation   
Take Care ! The insulation of control (Com1..X40) depends on the insulation of control voltage supply 
Additional insulation via opto-coupler or relay (without Safety-Functions) 
customer part 
1) 
1) 
see additional hints, chapter 2.4.2 
GND 
 
1.3.2 General 
Data 
 
Enclosure Rating - 
 
for Mounting in a Cubicle 
 IP20 
Operating Temperature Range 
 
EN 50178 / VDE 0160, class 3K3 
Storage Temperature Range 
 
-25°...+55° C 
Air Pressure 
 
86 kPa - 106 kPa 
Humidity 
 
5% - 85%,  40°C 
Operating Temp 
 
0...40°C 
 Reduced 
Operation 
 
De-rating of the Output Current 
1)
>40°...< 50°C 
 
2% /°C 
Altitude h 
 
≤ 1000m 
 Reduced 
Operation 
 
De-rating of the Output Current 
1)
h > 1000...
≤ 4000m 
 
1% / 100m 
Safety Over Voltage - Category of Power Circuit 
 
EN 50178 / VDE 0160, UL, cUL III,  
Pollution Degree - for Mounting in a Cubicle 
 
VDE / UL: 2 
Vibration Test in Accordance with 
DIN IEC 68-2-6, Test FC 
Condition for Testing 
 Frequency 
Range 
 Amplitude 
 Acceleration 
 
Test Time per Axis 
 
Frequency Sweep Speed 
 
 
 
 
10...57Hz   57...150Hz 
0,075 mm 
1g 
10 sweep cycle 
1 octave/min 
1) 
Use only fan-cooled devices. For reduced operating 
        conditions, no UL approval is available.