19.7.8  Log Sense Page E
This page contains the start-stop cycle information. 
Table 127: Log Sense Page E
The week and year that the device was manufactured shall be set in the parameter field defined by parameter code 0001h. The 
date of manufacture cannot be saved using the LOG SELECT command. The data is expected in numeric ASCII characters 
(30-39h) in the form YYYYWW. The accounting date specified by parameter code 0002h is a parameter that can be saved 
using the LOG SELECT command.
Byte
Bit
7
6
5
4
3
2
1
0
0
Reserved
Page code = 0Eh
1
Reserved
2-3
PageLength = 24h
4-5
Parameter Code = 0001h
6
DU=0
DS=1
TSD=0
ETC=0
TMC = 0
F&L = 00b
7
Parameter Length = 06h
8-11
Year of Manufacture (4 ASCII characters)
12-13
Week of Manufacture (2 ASCII characters)
14-15
Parameter Code 0002h
16
DU=0
DS=0
TSD=0
ETC=0
TMC = 0
F&L = 00b
17
Parameter Length = 06h
18-21
Accounting Date Year (4 ASCII characters)
22-23
Accounting Date Week (2 ASCII characters)
24-25
Parameter Code 0003h
26
DU=0
DS=1
TSD=0
ETC=0
TMC = 0
F&L = 00b
27
Parameter Length = 04h
28-31
Specified cycle count over device lifetime
32-33
Parameter Code 0004h
34
DU=0
DS=1
TSD=0
ETC=0
TMC = 0
F&L = 00b
35
Parameter Length = 04h
36-39
Accumulated start-stop cycles (4 byte binary number)