Hitachi HUS154530VLF400 User Manual

Page of 417
Hitachi Ultrastar 15K450 (FC-AL) Hard Disk Drive Specification
317 
21.6.5  Unit Attention Condition
The target generates a unit attention condition when one of the following occurs: 
The target has been reset 
This includes a power-on reset or a reset caused by a Target Reset Task Management function or Reset LIP. In all of 
these cases, a unit attention condition is generated for each initiator.   In addition, a process login (PRLI) will cause a 
Unit Attention Condition Power-On Reset for that initiator with an Additional Sense Code and Additional Sense 
Code Qualifier reported as Power-On Reset, Power-On Reset Occurred.
MODE SELECT command has been executed 
In this case, a unit attention condition is generated for all initiators except the one that issued the MODE SELECT 
command.  The Additional Sense Code and Additional Sense Code Qualifier reported is MODE PARAMETERS 
CHANGED. The unit attention condition is generated if any of the current page parameters are set by the MODE 
SELECT command. The target does not check to see that the old parameters are different from the new parameters. 
For example: If the initiator issues a MODE SENSE command with a page code to report the current values followed 
by a MODE SELECT command with the same parameter list, a unit attention condition is generated despite the fact 
that the current parameters were not changed from their previous value. However, if the target detects an illegal 
parameter or error condition prior to modifying the current parameters, a unit attention condition is not generated 
since the parameters were not set. The unit attention condition is also not generated if the MODE SELECT command 
parameter list does not include any pages and only the header or header/block descriptor is present. 
FORMAT UNIT command has been executed 
In this case, a unit attention condition is generated for all initiators except the one that issued the FORMAT UNIT 
command. The Additional Sense Code and Additional Sense Code Qualifier reported is NOT READY TO READY 
TRANSITION, (MEDIUM MAY HAVE CHANGED). This indicates that the block descriptor parameters from the 
last MODE SELECT command have been used and are now considered current values. 
WRITE BUFFER command to download microcode has been executed 
In this case, a unit attention condition is generated for all initiators except the one that issued the WRITE BUFFER 
command. The Additional Sense Code and Additional Sense Code Qualifier reported is MICROCODE HAS BEEN 
CHANGED. 
Commands Cleared by another initiator 
This unit attention condition is generated after an initiator sends a Clear Task Set Task Management function. The 
unit attention condition is generated for all other initiators with I/O processes that were either active or queued for the 
logical unit. The Additional Sense Code and Additional Sense Code Qualifier reported is COMMANDS CLEARED 
BY ANOTHER INITIATOR. 
LOG SELECT command with PCR bit has cleared parameters.
In this case, a unit attention condition is generated for all initiators except the one that issued the LOG SELECT com
mand. The additional sense code and additional sense code qualifier reported is Log Select Parameters Changed.
The registration or reservation made by a Persistent Reserve Out command was cleared by another initiator.
In this case, a unit attention condition is generated for the initiator that held the cleared registration or reservation.
A Predictive Failure Analysis threshold has been reached and the Method of Reporting field of mode page 1Ch is 2h.