Hitachi HUS154530VLF400 User Manual

Page of 417
Hitachi Ultrastar 15K450 (FC-AL) Hard Disk Drive Specification
348   
21.21.4.16  Predictive Failure Analysis
The Drive performs error log analysis and will alert the initiator of a potential failure. The initiator should determine if this 
device is the only device with error activity.
If this drive is the only drive attached to the initiator with error activity, service the drive using the procedures specified in Sec-
tion 21.21.1, “Drive Service Strategy” on page 339.
Note:
 Service for this drive can be deferred. The longer service is deferred, the more probable a failure can occur that will 
require immediate service.
If more than this drive is experiencing error activity, the drive is probably not at fault. Locate and service the outside source 
causing error activity on this drive.