Message Error
152A   Message reject error (SCSI only)
152C   Message parity error rcvd when no message sent by target (SCSI only)
B
44
00
Internal Target Failure
152D   Buffer CRC error on read
152E   Internal target failure - Host Interface
154A   Xfer Ready credit exceeded (FC-AL only)
154B   Xfer length error (FC-AL only)
1568 End-to-End Data Protection Guard check
1569 End-to-End Data Protection Application Tag check
156A End-to-End Data Reference Tag check
156B  ECC error in DRAM customer data area
156C  Uncorrectable DRAM ECC error
1570  Host interface CRC error
F645  Unrecovered Channel coarse tune timeout
F75C   Internal media access timeout
F761   Read/write command timeout
F772   DASH starting timeout
F773   ID table timeout
F774   Servo timeout
F775   Buffers timeout
F776   DASH done timeout
F777   DASH unknown timeout
F77A   Unrecovered Channel SBW timeout
F77D   Recovery timeout
F7B1   Overall command timeout
F7D0  Pre-load timeout
B
45
00
Select or Reselect Failure
152F   Selection reselection error (SCSI only)
B
47
00
SCSI Parity Error
1530   Message parity error - initiator (SCSI only)
1531   Message parity error - target (SCSI only)
B
47
03
Information Unit iuCRC Error Detected
1543   IU SCSI CRC error
B
48
00
Initiator Detected Error Message Received
1532   Initiator detected error message received (SCSI only)
B
49
00
Invalid Message Error